Page 77 - 2016 TGI CSR 電子書
P. 77

Violation:                              Improvement Measures


                                                                         Monitor water consumption based
                                                                          on water quality in backwash water
                                                                          and  adjust backwash schedule  to
                                                                          the effluent quantity.
                                                                      2. Companies are contracted to
                                                                        improve the  effluent  treatment
                                                                        system  to increase  its capacity and
                                                                        install  auto-monitoring  system  and
                                                                        other equipment to improve effluent
                                                                        quality. The work is estimated to be
                                                                        complete by July 2017.

                On the inspection day,  the  reading  of the effluent
                meter at the Hsinchu Factory  was zero  because  the
                wastewater treatment  equipment  was on the high-     The  effluent  meter was replaced and
                load automatic spoil  discharging mode,  lower  than   calibrated by an  external  service
                the  meter’s flow  range  (5.65m³/H~1357.175m³/H).    provider.
                This constituted to a violation of Article 65 of Water
                Pollution  Control Measures and Test Reporting
                Management Regulations.

                The  Environmental  Protection Bureau  of Hsinchu
                notified the Hsinchu Factory that there is inconsistency
                between the produced, discharged and stored           The factory made corrections on May
                quantities of the D-0699, D-0499, D-0902 and R-0402   10, 2016. The  factory checked  the
                waste from the filed inventory. The confirmation of the   produced  quantity, inventory  and
                produced quantities and inventory of these wastes is   discharged quantity before  filing  it
                very time consuming and the notification came during   online.
                holidays. Therefore the plant did not make corrections
                until  May 10,  2016  and violated Article 31.1. (2)  of
                Waste Disposal Act and received a NT$6,000 fine.

                                                                      1. Increase  sludge  pumping  frequency
                                                                        at the junction well  and  conduct
                Wastewater     treatment    equipment     operates      regular  maintenance  of wastewater
                automatically with liquid level control. The effluent   treatment equipment.
                sampled  on February  24,  2016  was the residual     2. Install  screens  to filter wastewater
                effluent in the equipment when it was not running. The   to reduce pump  malfunction  as  the
                residues in the pipes may have increased the sample’s   result of clogging.
                chemical oxygen demand to the level in violation of   3. Clean  the residue  in the effluent
                Article 7.1 of Water Pollution Control Act.
                                                                        discharge pipes  to prevent residues
                                                                        from affecting the water quality.          75
   72   73   74   75   76   77   78   79   80   81   82